Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Sens Actuators B Chem ; 392: 134085, 2023 Oct 01.
Article in English | MEDLINE | ID: covidwho-20240517

ABSTRACT

Sensitive and rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been a vital goal in the ongoing COVID-19 pandemic. We present in this comprehensive work, for the first time, detailed fabrication and clinical validation of a point of care (PoC) device for rapid, onsite detection of SARS-CoV-2 using a real-time reverse-transcription loop-mediated isothermal amplification (RT-LAMP) reaction on a polymer cartridge. The PoC system, namely PATHPOD, consisting of a standalone device (weight less than 1.2 kg) and a cartridge, can perform the detection of 10 different samples and two controls in less than 50 min, which is much more rapid than the golden standard real-time reverse-transcription Polymerase Chain Reaction (RT-PCR), typically taking 16-48 h. The novel total internal reflection (TIR) scheme and the reactions inside the cartridge in the PoC device allow monitoring of the diagnostic results in real-time and onsite. The analytical sensitivity and specificity of the PoC test are comparable with the current RT-PCR, with a limit of detection (LOD) down to 30-50 viral genome copies. The robustness of the PATHPOD PoC system has been confirmed by analyzing 398 clinical samples initially examined in two hospitals in Denmark. The clinical sensitivity and specificity of these tests are discussed.

2.
Sens Actuators B Chem ; 381: 133364, 2023 Apr 15.
Article in English | MEDLINE | ID: covidwho-2280540

ABSTRACT

Since December 2019, the rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has become a priority for public health. Although the lateral flow assay (LFA) sensor has emerged as a rapid and on-site SARS-CoV-2 detection technique, the conventional approach of using gold nanoparticles for the signaling probe had limitations in increasing the sensitivity of the sensor. Herein, our newly suggested methodology to improve the performance of the LFA system could amplify the sensor signal with a facile fabrication method by concentrating fluorescent organic molecules. A large Stokes shift fluorophore (single benzene) was encapsulated into polystyrene nanobeads to enhance the fluorescence intensity of the probe for LFA sensor, which was detected on the test line with a longpass filter under ultraviolet light irradiation. This approach provides comparatively high sensitivity with the limit of detection of 1 ng mL-1 for the SARS-CoV-2 spike protein and a fast detection process, which takes less than 20 min. Furthermore, our sensor showed higher performance than gold nanoparticle-based commercial rapid diagnostics test kits in clinical tests, proving that this approach is more suitable and reliable for the sensitive and rapid detection of viruses, bacteria, and other hazardous materials.

3.
Biosensors (Basel) ; 12(11)2022 Nov 03.
Article in English | MEDLINE | ID: covidwho-2282917

ABSTRACT

This article compares the applications of traditional gold and silver-based SERS substrates and less conventional (Pd/Pt, Cu, Al, Si-based) SERS substrates, focusing on sensing, biosensing, and clinical analysis. In recent decades plethora of new biosensing and clinical SERS applications have fueled the search for more cost-effective, scalable, and stable substrates since traditional gold and silver-based substrates are quite expensive, prone to corrosion, contamination and non-specific binding, particularly by S-containing compounds. Following that, we briefly described our experimental experience with Si and Al-based SERS substrates and systematically analyzed the literature on SERS on substrate materials such as Pd/Pt, Cu, Al, and Si. We tabulated and discussed figures of merit such as enhancement factor (EF) and limit of detection (LOD) from analytical applications of these substrates. The results of the comparison showed that Pd/Pt substrates are not practical due to their high cost; Cu-based substrates are less stable and produce lower signal enhancement. Si and Al-based substrates showed promising results, particularly in combination with gold and silver nanostructures since they could produce comparable EFs and LODs as conventional substrates. In addition, their stability and relatively low cost make them viable alternatives for gold and silver-based substrates. Finally, this review highlighted and compared the clinical performance of non-traditional SERS substrates and traditional gold and silver SERS substrates. We discovered that if we take the average sensitivity, specificity, and accuracy of clinical SERS assays reported in the literature, those parameters, particularly accuracy (93-94%), are similar for SERS bioassays on AgNP@Al, Si-based, Au-based, and Ag-based substrates. We hope that this review will encourage research into SERS biosensing on aluminum, silicon, and some other substrates. These Al and Si based substrates may respond efficiently to the major challenges to the SERS practical application. For instance, they may be not only less expensive, e.g., Al foil, but also in some cases more selective and sometimes more reproducible, when compared to gold-only or silver-only based SERS substrates. Overall, it may result in a greater diversity of applicable SERS substrates, allowing for better optimization and selection of the SERS substrate for a specific sensing/biosensing or clinical application.


Subject(s)
Metal Nanoparticles , Silver , Silver/chemistry , Spectrum Analysis, Raman/methods , Gold/chemistry , Limit of Detection , Silicon/chemistry , Metal Nanoparticles/chemistry
4.
Sensors (Basel) ; 23(2)2023 Jan 06.
Article in English | MEDLINE | ID: covidwho-2166826

ABSTRACT

Human antibodies are produced due to the activation of immune system components upon exposure to an external agent or antigen. Human antibody G, or immunoglobin G (IgG), accounts for 75% of total serum antibody content. IgG controls several infections by eradicating disease-causing pathogens from the body through complementary interactions with toxins. Additionally, IgG is an important diagnostic tool for certain pathological conditions, such as autoimmune hepatitis, hepatitis B virus (HBV), chickenpox and MMR (measles, mumps, and rubella), and coronavirus-induced disease 19 (COVID-19). As an important biomarker, IgG has sparked interest in conducting research to produce robust, sensitive, selective, and economical biosensors for its detection. To date, researchers have used different strategies and explored various materials from macro- to nanoscale to be used in IgG biosensing. In this review, emerging biosensors for IgG detection have been reviewed along with their detection limits, especially electrochemical biosensors that, when coupled with nanomaterials, can help to achieve the characteristics of a reliable IgG biosensor. Furthermore, this review can assist scientists in developing strategies for future research not only for IgG biosensors but also for the development of other biosensing systems for diverse targets.


Subject(s)
Biosensing Techniques , COVID-19 , Measles , Mumps , Rubella , Humans , COVID-19/diagnosis , Immunoglobulin G , Antibodies, Viral
5.
36th Center for Chemical Process Safety International Conference, CCPS 2021 - Topical Conference at the 2021 AIChE Spring Meeting and 17th Global Congress on Process Safety ; : 163-172, 2021.
Article in English | Scopus | ID: covidwho-2126010

ABSTRACT

The COVID-19 pandemic swept across the globe in the latter half of 2019, throughout 2020 and into 2021. In response, many companies implemented work from home policies, while others stopped operations entirely in an effort to limit the spread throughout their workforce and supporting communities. This containment strategy was not universally viable;long-term shutdowns impacted the economic viability of companies, and some industries were designated as an 'essential service' and thus continued operations. These employers faced the proposition of balancing the needs of the business and the community with a continued responsibility to provide a safe workplace for employees. This paper, and accompanying presentation, will demonstrate how the application of bowtie analysis, a commonly adopted methodology in high hazard industries, can help the risks associated with continued operation in a pandemic to be better understood and managed, thus ensuring the safety of both your personnel and business. © 36th Center for Chemical Process Safety International Conference, CCPS 2021 - Topical Conference at the 2021 AIChE Spring Meeting and 17th Global Congress on Process Safety.

6.
Diagnostics (Basel) ; 12(11)2022 Oct 28.
Article in English | MEDLINE | ID: covidwho-2123544

ABSTRACT

In this study, we evaluated the performance of the in-house developed rRT-PCR assay for SARS-CoV-2 RNA targeting the envelope (E) and nucleocapsid (N) genes with internal control as human RNase P. A total of 50 positive samples and 50 negative samples of SARS-CoV-2 were tested by a reference kit at site 1 and a subset (30 positives and 16 negatives) of these samples are tested blindly at site 2. The limit of detection (LoD) was calculated by using a replication-deficient complete SARS-CoV-2 genome and known copy numbers, where Pseudo-virus samples were used to evaluate accuracy. On site 1, among the 50 SARS-CoV-2 positive samples 24, 18, and eight samples showed high (Ct < 26), moderate (26 < Ct ≤ 32), and low (32 < Ct ≤ 38) viral load, respectively, whereas in site 2, out of 30 SARS-CoV-2 positive samples, high, moderate, and low viral loads were found in each of the 10 samples. However, SARS-CoV-2 was not detected in the negative sample. So, in-house assays at both sites showed 100% sensitivity and specificity with no difference observed between RT PCR machines. The Ct values of the in-house kit had a very good correlation with the reference kits. LoD was determined as 100 copies/mL. It also displayed 100% accuracy in mutant and wild-type SARS-CoV-2 virus. This Bangasure™ RT-PCR kit shows excellent performance in detecting SARS-CoV-2 viral RNA compared to commercially imported CE-IVD marked FDA authorized kits.

7.
J Immunoassay Immunochem ; 43(6): 579-604, 2022 Nov 02.
Article in English | MEDLINE | ID: covidwho-2028915

ABSTRACT

Lateral flow immunoassay is the leading Point of Care test and is becoming increasingly essential for its versatile properties. The attraction of lateral flow assay (LFA) has reached its prime position during recent SARS-CoV-2 pandemic and Ebola, Zika epidemics in third world countries where primary screening of the disease and financial issues are very important. During the last decade traditional methodology of LFA was limited to visual detection and qualitative assessment only. However, recently researchers are focusing on the development and improvement of this tool to enhance its specificity, assessment power (quantitative) to make it an alternative to traditional lab-based technology. Modifying working principle and instrumentation, combination of different modern molecular techniques such as Reverse transcription loop mediated isothermal amplification (RT-LAMP), Clustered regularly inter-spaced short palindromic repeat (CRISPR-Cas), Recombinase amplification polymerase (RPA), also association of image-based software, involvement of nanotechnology, implementation of LFA ruler have established authenticity and ultra-specific detection level. These leading immunochromatographic techniques offer simultaneous detection of different analytes from a single sample unit into one multiplex strip and provide the necessary information. This review is a foremost attempt to encompass recent advances of lateral flow assays in combination with molecular biology techniques along with improvements of assay components for improved diagnostic sensitivity and specificity. Some infectious disease diagnosis by LFA with its reporter and low detection limit have also been mentioned in this review.


Subject(s)
COVID-19 , Zika Virus Infection , Zika Virus , COVID-19/diagnosis , Humans , Immunoassay/methods , Pandemics , Recombinases , SARS-CoV-2 , Sensitivity and Specificity
8.
2021 Spring Meeting and 17th Global Congress on Process Safety, GCPS 2021 ; 2021.
Article in English | Scopus | ID: covidwho-1981151

ABSTRACT

The COVID-19 pandemic swept across the globe in the latter half of 2019,throughout 2020 and into 2021. In response,many companies implemented work from home policies,while others stopped operations entirely in an effort to limit the spread throughout their workforce and supporting communities. This containment strategy was not universally viable;long-term shutdowns impacted the economic viability of companies,and some industries were designated as anessential service and thus continued operations. These employers faced the proposition of balancing the needs of the business and the community with a continued responsibility to provide a safe workplace for employees. This paper,and accompanying presentation,will demonstrate how the application of bowtie analysis,a commonly adopted methodology in high hazard industries,can help the risks associated with continued operation in a pandemic to be better understood and managed,thus ensuring the safety of both your personnel and business. Copyright © American Institute of Chemical Engineers. All rights reserved.

9.
J Proteome Res ; 21(8): 2045-2054, 2022 08 05.
Article in English | MEDLINE | ID: covidwho-1947186

ABSTRACT

Targeted mass spectrometry-based platforms have become a valuable tool for the sensitive and specific detection of protein biomarkers in clinical and research settings. Traditionally, developing a targeted assay for peptide quantification has involved manually preselecting several fragment ions and establishing a limit of detection (LOD) and a lower limit of quantitation (LLOQ) for confident detection of the target. Established thresholds such as LOD and LLOQ, however, inherently sacrifice sensitivity to afford specificity. Here, we demonstrate that machine learning can be applied to qualitative PRM assays to discriminate positive from negative samples more effectively than a traditional approach utilizing conventional methods. To demonstrate the utility of this method, we trained an ensemble machine learning model using 282 SARS-CoV-2 positive and 994 SARS-CoV-2 negative nasopharyngeal swabs (NP swab) analyzed using a targeted PRM method. This model was then validated using an independent set of 200 positive and 150 negative samples and achieved a sensitivity of 92% relative to results obtained by RT-PCR, which was superior to a traditional approach that resulted in 86.5% sensitivity when analyzing the same data. These results demonstrate that machine learning can be applied to qualitative PRM assays and results in superior performance relative to traditional methods.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Machine Learning , Mass Spectrometry/methods , Sensitivity and Specificity
10.
J Mass Spectrom Adv Clin Lab ; 25: 27-35, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1885932

ABSTRACT

Introduction: Remdesivir (GS-5734) is a nucleoside analog prodrug with antiviral activity against several single-stranded RNA viruses, including the novel severe respiratory distress syndrome virus 2 (SARS-CoV-2). It is currently the only FDA-approved antiviral agent for the treatment of individuals with COVID-19 caused by SARS-CoV-2. However, remdesivir pharmacokinetics/pharmacodynamics (PK/PD) and toxicity data in humans are extremely limited. It is imperative that precise analytical methods for the quantification of remdesivir and its active metabolite, GS-441524, are developed for use in further studies. We report, herein, the first validated anti-viral paper spray-mass spectrometry (PS-MS/MS) assay for the quantification of remdesivir and GS-441524 in human plasma. We seek to highlight the utility of PS-MS/MS technology and automation advancements for its potential future use in clinical research and the clinical laboratory setting. Methods: Calibration curves for remdesivir and GS-441524 were created utilizing seven plasma-based calibrants of varying concentrations and two isotopic internal standards of set concentrations. Four plasma-based quality controls were prepared in a similar fashion to the calibrants and utilized for validation. No sample preparation was needed. Briefly, plasma samples were spotted on a paper substrate contained within pre-manufactured plastic cassette plates, and the spots were dried for 1 h. The samples were then analyzed directly for 1.2 min utilizing PS-MS/MS. All experiments were performed on a Thermo Scientific Altis triple quadrupole mass spectrometer utilizing automated technology. Results: The calibration ranges were 20 - 5000 and 100 - 25000 ng/mL for remdesivir and GS-441524, respectively. The calibration curves for the two antiviral agents showed excellent linearity (average R2 = 0.99-1.00). The inter- and intra-day precision (%CV) across validation runs at four QC levels for both analytes was less than 11.2% and accuracy (%bias) was within ± 15%. Plasma calibrant stability was assessed and degradation for the 4 °C and room temperature samples were seen beginning at Day 7. The plasma calibrants were stable at -20 °C. No interference, matrix effects, or carryover was discovered during the validation process. Conclusions: PS-MS/MS represents a useful methodology for rapidly quantifying remdesivir and GS-441524, which may be useful for clinical PK/PD, therapeutic drug monitoring (TDM), and toxicity assessment, particularly during the current COVID-19 pandemic and future viral outbreaks.

11.
Diagnostics (Basel) ; 12(5)2022 Apr 28.
Article in English | MEDLINE | ID: covidwho-1875516

ABSTRACT

Vertical flow assays (VFAs) or flow-through assays have emerged as an alternate type of paper-based assay due to their faster detection time, larger sample volume capacity, and significantly higher multiplexing capabilities. They have been successfully employed to detect several different targets (polysaccharides, protein, and nucleic acids), although in a limited number of samples (serum, whole blood, plasma) compared to the more commonly known lateral flow assays (LFAs). The operation of a VFA relies mainly on gravity, coupled with capillary action or external force to help the sample flow through layers of stacked pads. With recent developments in this field, multiple layers of pads and signal readers have been optimized for more user-friendly operation, and VFAs have achieved a lower limit of detection for various analytes than the gold-standard methods. Thus, compared to the more widely used LFA, the VFA demonstrates certain advantages and is becoming an increasingly popular platform for obtaining qualitative and quantitative results in low-resource settings. Considering the wide application of gold nanoparticles (GNPs) in VFAs, we will mostly discuss (1) the design of GNP-based VFA along with its associated advantages/disadvantages, (2) fabrication and optimization of GNP-based VFAs for applications, and (3) the future outlook of flow-based assays for point-of-care testing (POCT) diagnostics.

12.
Microbiol Spectr ; 10(3): e0102522, 2022 06 29.
Article in English | MEDLINE | ID: covidwho-1865143

ABSTRACT

Ensuring SARS-CoV-2 diagnostics that can reliably detect emerging variants has been an ongoing challenge. Due to the rapid spread of the Omicron variant, point-of-care (POC) antigen tests have become more widely used. This study aimed at (i) comparing the analytical sensitivity (LOD) of 4 POC antigen assays, BD Veritor, Abbott BinaxNow, Orasure InteliSwab and Quidel QuickVue, for the Omicron versus the Delta variant and (ii) verifying the reproducible detection of Omicron by the 4 antigen assays. The LOD for all four assays were evaluated using Omicron and Delta virus stocks quantified for infectivity and genome copies. The four assays detected all replicates of Omicron and Delta dilutions at 104 and 105 TCID50/mL, respectively. We quantified both viral stocks using droplet digital PCR (ddPCR), which revealed that the Omicron stock had equivalent copies of the N gene to Delta at a one log lower infectious virus. The Abbott BinaxNow and Orasure InteliSwab had the highest analytical sensitivity for Omicron while the Orasure InteliSwab and the Quidel QuickVue had the highest analytical sensitivity for Delta. When 14 SARS-CoV-2 real-time PCR positive nasal/nasopharyngeal swab samples (12 Omicron and 2 Delta, mean Ct = 19.1), were tested by the four assays, only the QuickVue detected all samples. Antigen test positivity correlated with recovery of infectious virus on cell culture in 9 out of 13 tested specimens from symptomatic, asymptomatic, unvaccinated, and vaccinated individuals. Although our study confirms the reduced analytical sensitivity of antigen testing compared to molecular methods, the Omicron variant was detectable by the four evaluated rapid antigen tests. IMPORTANCE In the manuscript, we report an evaluation of the capability of 4 point of care (POC) antigen assays, the BD Veritor, Abbott BinaxNow, Orasure InteliSwab and Quidel QuickVue to detect the Omicron variant of SARS-CoV-2, and we compared their analytical sensitivity for Omicron versus Delta. In this analysis we found that all four assays detected Omicron and Delta at 104 and 105 TCID50/mL, respectively. We further quantified the viral stocks used by droplet digital (ddPCR) and found that the Omicron stock had equivalent copies of the N gene to Delta at a one log lower infectious virus titer and that an increased RNA to infectious virus ratio may be contributing to discrepancies in limit of detection in Omicron compared to Delta. We evaluated 14 SARS-CoV-2 real-time PCR positive nasal/nasopharyngeal swab samples (12 Omicron and 2 Delta), with an average cycle threshold value of 19.1, and only the QuickVue showed 100% agreement.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Point-of-Care Systems , SARS-CoV-2/genetics , Sensitivity and Specificity
13.
JHEP Rep ; 4(7): 100496, 2022 Jul.
Article in English | MEDLINE | ID: covidwho-1804547

ABSTRACT

Background & Aims: Cirrhosis entails elevated risk of COVID-19-associated mortality. This study determined T cell-mediated and antibody reactivity against the spike 1 (S1) protein of SARS-CoV-2 among 48 patients with cirrhosis and 39 healthy controls after mRNA COVID-19 vaccination. Methods: SARS-CoV-2-specific T-cell reactivity was measured by induced level of T cell-derived interferon-γ (IFN-γ) in blood cells stimulated ex vivo with multimeric peptides spanning the N-terminal portion of S1. S1-induced IFN-γ was quantified before and after the 1st and 2nd vaccination (BNT162b2, Pfizer-BioNTech or mRNA-1273, Moderna) alongside serum IgG against the receptor-binding domain (RBD) within S1 (anti-RBD-S1 IgG). Results: T-cell reactivity against S1 was reduced in patients with cirrhosis after the 1st (p <0.001 vs. controls) and 2nd (p <0.001) vaccination. Sixty-eight percent of patients lacked detectable S1-specific T-cell reactivity after the 1st vaccination vs. 19% in controls (odds ratio 0.11, 95% CI 0.03-0.48, p = 0.003) and 36% remained devoid of reactivity after the 2nd vaccination vs. 6% in controls (odds ratio 0.12, 95% CI 0.03-0.59, p = 0.009). T-cell reactivity in cirrhosis remained significantly impaired after correction for potential confounders in multivariable analysis. Advanced cirrhosis (Child-Pugh class B) was associated with absent or lower T-cell responses (p <0.05 vs. Child-Pugh class A). The deficiency of T-cell reactivity was paralleled by lower levels of anti-RBD-S1 IgG after the 1st (p <0.001 vs. controls) and 2nd (p <0.05) vaccination. Conclusions: Patients with cirrhosis show deficient T-cell reactivity against SARS-CoV-2 antigens along with diminished levels of anti-RBD-S1 IgG after dual COVID-19 vaccination, highlighting the need for vigilance and additional preventative measures. Clinical trial registration: EudraCT 2021-000349-42. Lay summary: T cells are a pivotal component in the defence against viruses. We show that patients with cirrhosis have impaired SARS-CoV-2-specific T-cell responses and lower antibody levels after mRNA vaccination against COVID-19 compared with healthy controls. Patients with more advanced liver disease exhibited particularly inferior vaccine responses. These results call for additional preventative measures in these patients.

14.
Sens Actuators B Chem ; 362: 131765, 2022 Jul 01.
Article in English | MEDLINE | ID: covidwho-1757833

ABSTRACT

SARS-CoV-2 is one of the greatest threats to global human health. Point-of-care diagnostic tools for SARS-CoV-2 could facilitate rapid therapeutic intervention and mitigate transmission. In this work, we report CRISPR-Cas13a cascade-based viral RNA (Cas13C) assay for label-free and isothermal determination of SARS-CoV-2 and its mutations in clinical samples. Cas13a/crRNA was utilized to directly recognize the target of SARS-CoV-2 RNA, and the recognition events sequentially initiate the transcription amplification to produce light-up RNA aptamers for output fluorescence signal. The recognition of viral RNA via Cas13a-guide RNA ensures a high specificity to distinguish SARS-CoV-2 from MERS-CoV and SARS-CoV, as well as viral mutations. A post transcription amplification strategy was triggered after CRISPR-Cas13a recognition contributes to an amplification cascade that achieves high sensitivity for detecting SARS-CoV-2 RNA, with a limit of detection of 0.216 fM. In addition, the Cas13C assay could be able to discriminate single-nucleotide mutation, which was proven with N501Y in SARS-Cov-2 variant. This method was validated by a 100% agreement with RT-qPCR results from 12 clinical throat swab specimens. The Cas13C assay has the potential to be used as a routine nucleic acid test of SARS-CoV-2 virus in resource-limited regions.

15.
International Conference on Computing, Communication, Electrical and Biomedical Systems, ICCCEBS 2021 ; : 353-368, 2022.
Article in English | Scopus | ID: covidwho-1750473

ABSTRACT

COVID-19 is one of the dangerous viruses that appears in 2020. The virus has gained popularity with its massive spread across the countries. The number of casualties has increased dramatically, which led many countries to declare a state of emergency as a result of the outbreak of this epidemic and their inability to control it. Several studies and researches have emerged to shed light on the mechanism of the virus and ways to prevent it, making it easier to control in the future. The World Health Organization (WHO) has begun to publish detailed numbers of injuries, deaths, and recovery cases and has given many advices, including the imposition of a total and partial curfew in many areas in addition to emphasizing the principle of social divergence in order to prevent the rapid spread of the virus among groups of society. The main goal of this paper is to design a system that used genetic algorithms (GAs) and the principles of linked open data (LOD) for improving the immunity system by enhancing social divergence. The system starts using GA for the purpose of finding the characteristics that must be present in a person who is dangerous to society in order to get away from him as much as possible. After taking these features, the system will take the values of these features and add it to the features for all persons in order to check it in the future and give alarm to all their friends or people around them. The RDF (Resource Description Framework) is a standard model for data interchange on the Web. The main idea for using RDF in this paper is finding a proper representation for user personal file and give the flexibility to connect many personal files in order to find a deep information and can reach an unknown person from known person using the FOAF (Friend Of A Friend) and vCard (virtual card) as a standard for vocabularies. The system takes the Statistics from the WHO which show the total infected cases in all countries arranged in decreasing order. The system gives a good result for analyzing the COVID-19 virus information and detecting the infected (possible infected) person and send warning to all nearest people and his friend and family, because sometimes the person has no coronavirus symptoms but he is infected so we need a technique for detecting that virus and take a proper action as soon as possible. © 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG.

16.
Toxicol Rep ; 8: 646-656, 2021.
Article in English | MEDLINE | ID: covidwho-1525967

ABSTRACT

Humans are frequently exposed to Quaternary Ammonium Compounds (QACs). QACs are ubiquitously used in medical settings, restaurants, and homes as cleaners and disinfectants. Despite their prevalence, nothing is known about the health effects associated with chronic low-level exposure. Chronic QAC toxicity, only recently identified in mice, resulted in developmental, reproductive, and immune dysfunction. Cell based studies indicate increased inflammation, decreased mitochondrial function, and disruption of cholesterol synthesis. If these findings translate to human toxicity, multiple physiological processes could be affected. This study tested whether QAC concentrations could be detected in the blood of 43 human volunteers, and whether QAC concentrations influenced markers of inflammation, mitochondrial function, and cholesterol synthesis. QAC concentrations were detected in 80 % of study participants. Blood QACs were associated with increase in inflammatory cytokines, decreased mitochondrial function, and disruption of cholesterol homeostasis in a dose dependent manner. This is the first study to measure QACs in human blood, and also the first to demonstrate statistically significant relationships between blood QAC and meaningful health related biomarkers. Additionally, the results are timely in light of the increased QAC disinfectant exposure occurring due to the SARS-CoV-2 pandemic. MAIN FINDINGS: This study found that 80 % of study participants contained QACs in their blood; and that markers of inflammation, mitochondrial function, and sterol homeostasis varied with blood QAC concentration.

17.
Sens Actuators B Chem ; 351: 130975, 2022 Jan 15.
Article in English | MEDLINE | ID: covidwho-1475063

ABSTRACT

As the world has been facing several deadly virus crises, including Zika virus disease, Ebola virus disease, severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and Coronavirus disease 2019 (COVID-19), lateral flow assays (LFAs), which require minimal equipment for point-of-care of viral infectious diseases, are garnering much attention. Accordingly, there is an increasing demand to reduce the time and cost required for manufacturing LFAs. The current study introduces an equipment-free method of salt-mediated immobilization of nucleic acids (SAIoNs) for LFAs. Compared to general DNA immobilization methods such as streptavidin-biotin, UV-irradiation, and heat treatment, our method does not require special equipment (e.g., centrifuge, UV-crosslinker, heating device); therefore, it can be applied in a resource-limited environment with reduced production costs. The immobilization process was streamlined and completed within 30 min. Our method improved the color intensity signal approximately 14 times compared to the method without using SAIoNs and exhibited reproducibility with the long-term storage stability. The proposed method can be used to detect practical targets (e.g., SARS-CoV-2) and facilitates highly sensitive and selective detection of target nucleic acids with multiplexing capability and without any cross-reactivity. This novel immobilization strategy provides a basis for easily and inexpensively developing nucleic acid LFAs combined with various types of nucleic acid amplification.

18.
J Mass Spectrom Adv Clin Lab ; 21: 31-41, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1401638

ABSTRACT

More than a year after the COVID-19 pandemic was declared, the need still exists for accurate, rapid, inexpensive and non-invasive diagnostic methods that yield high specificity and sensitivity towards the current and newly emerging SARS-CoV-2 strains. Compared to the nasopharyngeal swabs, several studies have established saliva as a more amenable specimen type for early detection of SARS-CoV-2. Considering the limitations and high demand for COVID-19 testing, we employed MALDI-ToF mass spectrometry in the analysis of 60 gargle samples from human donors and compared the resultant spectra against COVID-19 status. Several standards, including isolated human serum immunoglobulins, and controls, such as pre-COVID-19 saliva and heat inactivated SARS-CoV-2 virus, were simultaneously analyzed to provide a relative view of the saliva and viral proteome as they would appear in this workflow. Five potential biomarker peaks were established that demonstrated high concordance with COVID-19 positive individuals. Overall, the agreement of these results with RT-qPCR testing on nasopharyngeal swabs was ≥90% for the studied cohort, which consisted of young and largely asymptomatic student athletes. From a clinical standpoint, the results from this pilot study suggest that MALDI-ToF could be used to develop a relatively rapid and inexpensive COVID-19 assay.

20.
Microchem J ; 167: 106305, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1198979

ABSTRACT

Since December 2019, we have been in the battlefield with a new threat to the humanity known as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this review, we describe the four main methods used for diagnosis, screening and/or surveillance of SARS-CoV-2: Real-time reverse transcription polymerase chain reaction (RT-PCR); chest computed tomography (CT); and different complementary alternatives developed in order to obtain rapid results, antigen and antibody detection. All of them compare the highlighting advantages and disadvantages from an analytical point of view. The gold standard method in terms of sensitivity and specificity is the RT-PCR. The different modifications propose to make it more rapid and applicable at point of care (POC) are also presented and discussed. CT images are limited to central hospitals. However, being combined with RT-PCR is the most robust and accurate way to confirm COVID-19 infection. Antibody tests, although unable to provide reliable results on the status of the infection, are suitable for carrying out maximum screening of the population in order to know the immune capacity. More recently, antigen tests, less sensitive than RT-PCR, have been authorized to determine in a quicker way whether the patient is infected at the time of analysis and without the need of specific instruments.

SELECTION OF CITATIONS
SEARCH DETAIL